This Curtech Solar Controller has some new features which will not only help maintain your battery charge but will also provide you with information so you are in control.

One of the features is the ability not to only show a battery voltage but this regulator will display 100% in the bar graph at the top of the screen when the battery is fully charged. It takes the guess work out of knowing if your battery is charged or not.

In addition to this, by a simple press of the voltage button the Amps which are being input to your battery will display.

By pressing this button again the accumulated Amps output to your battery will be displayed.

This Curtech Regulator will not only charge the standard AGM, Gel and Flood batteries it can also charge LiFePO4, LTO (Lithium Titanium Oxide) and Calcium Batteries.

Electrical Parameters
Rated solar panel Amps for CT12-10A / CT12-20A 10/20Amp
Normal input Solar cell array voltage 15-22VDC
Max. solar cell array voltage (output has no load) 25VDC
The controller lowest operating voltage (at solar or battery side) 8VDC
Standby current consumption at night 5mA Max
Maximum voltage drop – Solar panel to battery 0.25VDC
Protection
Against reverse polarity or short circuit
No reverse current from battery to solar at night
Over temperature protection during charging 65°C
Electrical parts
Input output terminal M4 terminals
Temperature sensor port (Press and Release type) DA 250-350 2P
Physical Parameters
Controller material Plastic, Standard ABS
Power terminal maximum stranded wire size #12 AWG stranded 3mm2
Mounting Vertical wall mounting
IP grade IP65
Net weight Approx. 300g
Dimensions 130 x 102 x 27mm
Environmental characteristics
Operating temperature -25 to 50°C
Storage temperature -40 to 85°C
Operating Humidity range 100% no condensation
Charging Characteristics
Minimum battery start charging voltage 3VDC
Soft start charging voltage 3-10VDC +/-0.2
Soft start charging current (50% PWM duty) Up to 5/10Amp
Bulk charge voltage 10-14VDC +/-0.2
Absorption charging voltage at 25°C
  • LTO type battery
14.0VDC +/-0.2
  • Gel type battery
14.1VDC +/-0.2
  • LiFePO4 battery
14.4VDC +/-0.2
  • AGM type battery (default setting)
14.4VDC +/-0.2
  • WET type battery
14.7VDC +/-0.2
  • Calcium type battery
14.9VDC +/-0.2
Absorption transits to Equalizing or Float condition
  • Charging current drops to
0.5Amp +/-0.1
  • or Absorption charging timer timed out
4 Hours
Equalization charging active (Only for WET or Calcium battery)
  • Battery voltage discharged to less than
10VDC +/-0.2
  • Automatic equalizing charging periodical
28 Days
Equalization charging voltage at 25°C 15.5VDC +/-0.2
Equalization charging timer timed out 2 Hours
Float charging voltage at 25°C
  • For LTO and LiFePO4 battery
13.4VDC +/-0.2
  • For Gel, AGM, WET, Calcium battery
13.6VDC +/-0.2
Voltage control accuracy +/- 1%
Battery temperature compensation coefficient -24 mV/°C
Temperature compensation range -20 to +50°C